Show simple item record

dc.contributor.authorNdinda, Elizabeth Nthambi
dc.date.accessioned2019-04-03T05:57:25Z
dc.date.available2019-04-03T05:57:25Z
dc.date.issued2016-03
dc.identifier.urihttp://ir.mksu.ac.ke/handle/123456780/4218
dc.description.abstractThis cumulative thesis aimed at the investigation of alternative sorbents based on molecularly imprinted polymers (MIPs) and multi-walled carbon nanotubes (MWCNTs) for monitoring of polychlorinated biphenyls (PCBs) in various environmental matrices. The first section of the thesis is the general introduction, where the concept of molecular imprinting and the three main imprinting approaches are discussed. The non-covalent imprinting approach owing to its simplicity and availability of functional monomers is the preferred approach, and was exclusively applied in this thesis. The emerging term “class selective MIPs” for simultaneous recognition and detection of a group of similarly structured compounds is also discussed, and was adopted during these studies. The current knowledge on use of MIPs and MWCNTs in sample pre-treatment and the need for validation of affordable analytical protocols for monitoring of PCBs is discussed. Facts about PCBs are presented, and the particular concern about PCBs in the Kenyan environment is discussed with a view of identifying the existing technology gaps, as far as their monitoring is concerned. The second section contains the 4 papers that make up this thesis. Paper I sought to develop a reliable and affordable column for clean-up of extracts during the determination of PCBs in complex matrices. Thus prepared cartridges based on MIPs were successfully applied for the quantification of PCBs in sediments and soil. Motivated by the performance of the cartridges and their re-usability, further determination of PCBs in soils from various solid waste disposal sites and sediments from a second river was achieved, and the results are included at the end of Paper I. Paper II introduces two different strategies for imprinting of PCBs based on chlorinated benzene and xylenes serving as porogenic templates, whereby porogenic fragments present a particularly attractive option for chlorinated compounds. Paper III discusses the potential of using MWCNTs as sorbents for the quantitative pre-concentration of PCBs from aqueous samples. Thereby, it was established that these sorbents work well with highly chlorinated constituents, and may also be applicable in water purification, yet only in the absence of oxidizing agents. Paper IV is a review on strategies that have been applied to synthesis polymers selective to polychlorinated aromatic compounds (PACs), and subsequent application of these polymers in determination of PACs in the environment.en_US
dc.language.isoen_USen_US
dc.titleDevelopment of Selective Sorbent Materials for the Determination of Polychlorinated Biphenyls (PCBs) in the Environmenten_US
dc.typeThesisen_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record